Ground Loop Configurations
Your contractor will recommend one of these four ground loop designs.
The recommendation will be based on: the size of your home and yard; your home's design heat loss; soil conditions; equipment sizing; use of a desuperheater; required entering heat transfer fluid temperature; and the availability and quality of groundwater.
Horizontal Closed Loop
Best for:
- Rural areas where space permits; areas where soils can be easily excavated; land with high moisture content is optimal for these systems.
Considerations:
- Requires more land area than any other loop system. The pipe is generally buried in a trench, usually 2 to 3 metres (6 to 10 feet) deep in one continuous loop or a series of parallel loops.
- Proper design is critical, since horizontal pipe lengths can vary between 91 and 914 metres (300 and 3,000 feet) of pipe per tonne of heat output.
- Rural properties of over one acre are typically best suited for horizontal configuration.
- Not recommended in dry sands and gravels.
Horizontal loop designs include one-pipe, two-pipe, four-pipe, and slinky coil configurations. The most common are two and four-pipe configurations.
[ Back to List ]
Vertical Closed Loop
Best for:
- Homes with limited available land area, or where other loop configurations are not cost-effective.
Considerations:
- Vertical loops require fewer feet of piping than horizontal loops, since ground temperatures are more constant at a depth of about 6 metres (20 feet) or deeper.
- Vertical boreholes measure approximately 13–18 centimeters (5–7 inches) in diameter and are typically spaced 10–20 feet apart.
- A pair of 3/4–1 1/4 inch pipes are inserted in the borehole connected by a u-bend assembly on the bottom. The pipes in each of the boreholes are tied together in a trench 4–6 feet under grade.
- Proper design is essential since pipe length can vary from 91 to 183 metres (300 to 600 feet) per tonne of heat output.
- Your contractor may drill a test borehole to determine soil conditions to confirm loop length and design prior to system installation.
[ Back to List ]
Well-to-well or Open Loop
Best for:
- Homes with access to a good supply and quality of well water. Open loop systems extract heat directly from well water. Well water is pumped to the heat pump system from a supply well, and is then returned to a second well or "return well".
Considerations:
- Typically, the entering water temperature of an open loop system is approximately 6 C higher than a closed loop system. Higher entering water temperatures can lead to improved efficiency of the geothermal heat pump system.
- Water sources with high levels of salt, chlorides or other minerals can cause premature system failure or inefficient operation.
- Annual cleaning and maintenance of the heat exchanger(s) by your installation contractor in your heat pump furnace unit will be required to reduce mineral scaling.
- Pumping power may become an issue in installations that require deep supply wells.
- Approvals from the appropriate environmental authorities in your area may be required.
[ Back to List ]
Lake or Pond Closed Loop
Best for:
- Areas with a pond or lake nearby and poor drilling/excavation conditions, where the loop field can be submerged in water, rather than buried in the ground.
Considerations:
- Approvals from the appropriate environmental authorities in your area are required (i.e. Department of Fisheries and Oceans).
- The loop field must be:
- properly anchored to remain on the bottom of the body of water;
- submerged deep enough under water;
- protected at the shoreline to avoid being dragged away by the movement of spring ice break-up.
- Lake/pond system is an extremely specialized configuration, so important that an installation contractor has sufficient experience and understands all aspects of this type of installation